AS NZS 3003-2018

$97.00

Electrical installations – Patient areas

2018 Edition

Published by Standards Australia, 26/03/2018

 

Description

AS NZS 3003 – 2018 Edition – Electrical installations – Patient areas

AS NZS 3003 sets out the requirements for areas in new electrical installations and for alterations and repairs of patient areas in existing electricalinstallations where the organization/entity responsible for that electrical installation has determined that low-voltage medical electrical equipment will be used on a patient. AS NZS 3003 covers special patient areas, including homecare installations and transportable vehicles. It also contains requirements for identification, inspection and testing of patient areas.

Electrical installations in patientareas shall be carried outin accordance with AS NZS 3000, except as varied herein, and with the additional requirements of this Standard.

The decisions made by the responsible organization/entity in determining classification of patient areas need to be based on the medical procedures undertaken in each area. Advice on whether particular patient areas should be wired as body-protected or cardiac-protected electrical areas is specified in AS/NZS 2500. The responsible organization/entity should refer to the safe practice code in AS/NZS 2500 for advice on how these decisions should be based on the type of procedures undertaken in each area and thelevel of protection against electric shock afforded in the medical electrical equipment available for these procedures.

While this Standard is intended to apply to new installations or extensions, some guidance is given concerning conversion of older installations.

Areas other than patient areas are not covered by this Standard, but are covered by the relevant requirements of AS/NZS 3000.
Requirements for mobile trolleys supporting electrical equipment are given in AS/NZS 3551.
Requirements for emergency lighting are given in AS/NZS 2293.1.
Requirements for emergency powersystems in hospitals are givenin AS/NZS 3009.
In New Zealand, mobile medical connectable installations shallbe in accordance with the requirements of this Standard and NZS 6115.

This Standard nominates specific maximum values of electromagnetic interference. This matter needs careful consideration at the design stage. In somepatient areas, these values need to be measured.

NOTE: See Section 6 for alterations to equipotential earthing in existing installations.

General Product Information:

Edition 6th Edition
Document Type PDF
Document Language English
Committee HT-021
ISBN 9781760720247
Pages 85
Publisher Standards Australia(AS)
Status Current

Amendments, rulings, supplements, and errata include: